Skip to main content

ijamri

International Journal of Advanced Multidisciplinary Research and Innovation
E-ISSN: 3107-6157   |   Impact Factor: 3.94
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Call for Paper Volume 2, Issue 6 (November-December 2026) — Submit your research for the November-December 2026 issue. Call for Paper Volume 2, Issue 6 (November-December 2026) — Submit your research for the November-December 2026 issue. Call for Paper Volume 2, Issue 6 (November-December 2026) — Submit your research for the November-December 2026 issue.

Comparative Static Performance of Carbon Fibre-Reinforced Polymer and Steel Cables in Beam-String Structures: Finite Element Analysis and Numerical Verification

📚 Volume 2, Issue 5, September-October 2026 | Published on : 30-10-2026
Published
Authors
Fan Donghao, Aiman Al-Odaini
Abstract
Beam-string structures (BSSs) utilize cables to achieve long span structures. Stiffness and mass of cables are system properties that depend on material of construction. This study emulates steel and carbon fiber reinforced polymer (CFRP) cables to assess their effect on behavior of BSSs. A general-purpose computational software environment was interfaced with Python to programmatically generate and solve a BSS model subjected to “static loading. Steel and CFRP cables were embedded in a reusable, reduced order, finite element model (ROM-FEM). The ROM-FEM incorporates Euler-Bernoulli beams and equivalent springs to represent cable segments. The baseline model consists of a 12 m span, loaded by a 10 kN/m uniform load, and prestressed by a 200 kN load in the CFRP cable. In the steel cable case, the mid-span displacement was 2.835 mm. In the CFRP case, mid-span deflection was computed to be 3.590 mm. This represents an approximately 26.6% increase, attributable to the Steel-CFRP stiffness assumption. A 800 mm2 cross sectional area for the CFRP cable reduced computed mid span deflection to 2.835 mm. In the steel case, a change in prestress from 100 kN to 300 kN resulted in a change of computed mid span deflection from 2.843 to 2.827 mm. Computed mid span deflections in the equal area CFRP case varied from 3.603 to 3.577 mm. Changes in mesh size were performed to assess solution accuracy. As the idealization of the cable-strut subsystem by the model presents equivalent spring elements, the results presented herein are dependent on the assumptions stated and should not be construed as ANSYS results or experimental results for the complete system. Trend analysis and model improvement are the primary focus of the model; design conclusions for a particular prototype would require experimental results coupled with a complete, geometrically correct finite element model.
Keywords
beam–string structure carbon-fibre-reinforced polymer steel cable finite-element analysis static performance prestress sensitivity load–displacement response reduced-order modelling mesh verification
Publication Details
Research Area
Engineering (civil, mechanical, electrical, etc.)
Country
Malaysia
Published
October 30, 2026